High-Frequency Vibrator Available Units Table
ICV / HBM (Internal Vibrators)
| Models | ICV / HBM (Internal Vibrators) | |||||||
|---|---|---|---|---|---|---|---|---|
| HBM30 | φ40 | φ50 | φ60 | CSV50 | ADV40 | ADV50 | ||
| Inverter | HC111B/(RC) | 3 | 1 | 1 | - | 1 | 1 | 1 |
| HC113B | 4 | 2 | 1 | - | 2 | 1 | 1 | |
| HC116B | 5 | 3 | 2 | 1 | 3 | 2 | 1 | |
| HC230A/B | 10 | 6(5) | 4(3) | 2 | 6(5) | 4 | 2 | |
| H260B | 20 | 13(12) | 8(6) | 5(4) | 13(12) | 11 | 5 | |
| Generator | HAG122MF/MH | 6 | 4 | 2 | 1 | 4 | 3 | 1 |
| HAG134MF/MHA | 11 | 7(6) | 4(3) | 3(2) | 7(6) | 5 | 2 | |
HKM (Woodpecker / Iron)
| Models | HKM (Woodpecker / Iron) | ||||
|---|---|---|---|---|---|
| 5CSK/55PSK | 50PSK | 154VS | 304VS | ||
| Inverter | HC111B/(RC) | 4 | 4 | 2 | 1 |
| HC113B | 5 | 5 | 3 | 1 | |
| HC116B | 8 | 8 | 5 | 2 | |
| HC230A/B | 18(14) | 18(14) | 10(8) | 4(3) | |
| H260B | 36(30) | 36(30) | 20(18) | 9(7) | |
| Generator | HAG122MF/MH | 10 | 10 | 6 | 2 |
| HAG134MF/MHA | 20(16) | 20(16) | 11(9) | 5(4) | |
HKM (Vibration Motor)
| Models | HKM (Vibration Motor) | ||||
|---|---|---|---|---|---|
| 30LF(S) | 40BL | 55LF(S)A | 75LF(S)A | ||
| Inverter | HC111B/(RC) | 1 | - | - | - |
| HC113B | 1 | - | - | - | |
| HC116B | 2 | 1 | 1 | 1 | |
| HC230A/B | 4(3) | 3(2) | 2 | 2 | |
| H260B | 9(7) | 6(4) | 5 | 4 | |
| Generator | HAG122MF/MH | 2 | 1 | 1 | 1 |
| HAG134MF/MHA | 5(4) | 3(2) | 3(2) | 2 | |
* The numbers shown in parentheses ( ) in the tables indicate the number of vibrators that can be operated when all units are assumed to be running continuously under overload conditions simultaneously.
* High-frequency vibrators must be operated only with Exen-approved high-frequency power supply units.