High-Frequency Vibrator Available Units Table

ICV / HBM (Internal Vibrators)

ModelsICV / HBM (Internal Vibrators)
HBM30φ40φ50φ60CSV50ADV40ADV50
InverterHC111B/(RC)311-111
HC113B421-211
HC116B5321321
HC230A/B106(5)4(3)26(5)42
H260B2013(12)8(6)5(4)13(12)115
GeneratorHAG122MF/MH6421431
HAG134MF/MHA117(6)4(3)3(2)7(6)52

HKM (Woodpecker / Iron)

ModelsHKM (Woodpecker / Iron)
5CSK/55PSK50PSK154VS304VS
InverterHC111B/(RC)4421
HC113B5531
HC116B8852
HC230A/B18(14)18(14)10(8)4(3)
H260B36(30)36(30)20(18)9(7)
GeneratorHAG122MF/MH101062
HAG134MF/MHA20(16)20(16)11(9)5(4)

HKM (Vibration Motor)

ModelsHKM (Vibration Motor)
30LF(S)40BL55LF(S)A75LF(S)A
InverterHC111B/(RC)1---
HC113B1---
HC116B2111
HC230A/B4(3)3(2)22
H260B9(7)6(4)54
GeneratorHAG122MF/MH2111
HAG134MF/MHA5(4)3(2)3(2)2

* The numbers shown in parentheses ( ) in the tables indicate the number of vibrators that can be operated when all units are assumed to be running continuously under overload conditions simultaneously. 
* High-frequency vibrators must be operated only with Exen-approved high-frequency power supply units.